Coaltech Research Association

Development of Seam-Specific Strength Formulae for South African Collieries

Statistical back analysis of an expanded collapse database, testing power, linear and non-linear strength models, for rock engineers setting pillar safety factors.

by M.D.G. Salamon, I. Canbulat and J.A. Ryder | January 2006

What this report found

Back analysis of 77 collapsed and 245 uncollapsed pillar cases showed that much of the scatter in pillar strength comes from differences between coalfields, so a single national formula is unrealistic. Seam specific formulae were derived for the major coalfields; Free State and KwaZulu Natal data remained too sparse. The lognormal safety factor distribution was retained.

R1500,00

Description

Related Products

Developing a Mechanised Cleaning System – for Cleaning Under and Around Moving Conveyors

2013

Follow on review of mechanised conveyor cleaning equipment close to being usable underground, flameproof and not, written to help the coal industry agree which options to develop.

What this report foundNo flameproof mechanised system for cleaning under and around moving conveyors was found to exist anywhere.

R1500,00

R1500,00

What this report found

No flameproof mechanised system for cleaning under and around moving conveyors was found to exist anywhere. Of more than 200 mini machinery manufacturers identified worldwide, few build for mining, and only one or two products were near ready for surface use. Manufacturer interest in mining applications has since risen, but the industry has not settled on which technology to back.

SJ Mangena

Dense-medium Fine Coal Processing: Tests Conducted at South Witbank Coal Mine

GJ de Korte

2003

Pilot scale dense medium testing on fine coal at a Witbank colliery after the plant was moved from an earlier site, with sampling, efficiency and magnetite results for plant designers.

What this report foundThe fine coal dense medium pilot plant was rebuilt at South Witbank Coal Mine and run on fine coal, with tests covering single, double and three stage...

R1500,00

R1500,00

GJ de Korte

200319 pages

What this report found

The fine coal dense medium pilot plant was rebuilt at South Witbank Coal Mine and run on fine coal, with tests covering single, double and three stage processing, the effect of recirculating load, magnetite size and losses, separation efficiency and continuous operation. The fast screen could not deliver the required capacity and was replaced by dewatering cyclones to deslime the feed.

Grant van Heerden

Shopping Basket