Treatment of Sulphate Rich Effluents with the Combined Electrolytic/Biological Process
Laboratory work on producing hydrogen by electrolysis as the energy source for sulphate reducing bacteria, aimed at cutting the running cost of treating sulphate rich mine water.
by JP Maree, JJ Smit & BJ Bladergroen | April 2003
Hydrogen for biological sulphate removal can be generated on site by electrolysis more cheaply than it can be bought. Stainless steel electrodes in acid mine drainage gave hydrogen at about a third of the bought in price while oxidising ferrous iron to ferric, which helps downstream treatment. Iron and zinc electrodes dissolved too quickly to be viable.
R1500,00
Description
Related Products
Demonstrate the efficiency of UAV-GPR for assessment of rehabilitation sites and detection of subsurface cavities
2023
Field trials at two South African collieries comparing drone mounted ground penetrating radar against ground based surveys, for measuring rehabilitation soil thickness and locating shallow voids. For rehabilitation teams.
What this report foundGround based radar mapped rehabilitation soil profiles well enough to replace much of the auger sampling normally needed, and a 100 MHz system picked out...
R1500,00
Ground based radar mapped rehabilitation soil profiles well enough to replace much of the auger sampling normally needed, and a 100 MHz system picked out anomalies at about 5 to 6 m depth that were likely old mining voids and related subsidence. Penetration below roughly 6 m needs lower frequencies, which cost resolution and require larger antennas.
Collation of Historic Thermal Imagery
2008
Pilot exercise pulling scattered thermal survey datasets held by companies and research bodies into one mapping system, with a view to tracking coal fires and mine water discharge.
What this report foundExisting thermal imagery of the Witbank coalfield was traced to its holders and assessed for format, quality, resolution and coverage, then brought into one...
R1500,00
Existing thermal imagery of the Witbank coalfield was traced to its holders and assessed for format, quality, resolution and coverage, then brought into one geographic information system with supporting metadata. Satellite thermal bands give a regional picture only; detailed mapping of coal fires or acid drainage discharge needs high resolution aerial surveys.
Dry Processing of Coal – Progress Report: Tests Conducted on the IMS / Slater Coal Marketing Allair Dry Jig
2016
Test work on a dry jig installed at a Balmoral site, covering coal sized below 50 mm and duff below 12 mm, for producers considering waterless beneficiation.
What this report foundA 30 tonne per hour pilot Allair dry jig upgraded run of mine coal to thermal coal specification, but could not effectively beneficiate finer duff.
R1500,00
201613 pages
A 30 tonne per hour pilot Allair dry jig upgraded run of mine coal to thermal coal specification, but could not effectively beneficiate finer duff. Cut point densities and EPM values matched other dry processing equipment, though the jig appeared to give better control of the parameters governing separation. Four tests ran on run of mine coal and two on duff.
Real-time Plant Efficiency Measurement
2002
Assessment of the measurement and control equipment available to coal preparation plants, with recommendations for plant metallurgists on which instruments to add first.
What this report foundNo single method gives a continuous, real time report on how a coal preparation plant is performing.
R1500,00
200230 pages
No single method gives a continuous, real time report on how a coal preparation plant is performing. Mass meters converted to yield values, on-line ash and moisture monitors, load cell chutes and automatic medium density control together supply most of what is needed. Measuring discard and slimes tonnages, particularly slimes disposal, remains the weakest point in plant accounting.