Pilot tests of a waterless de-stoning unit on raw coals from four South African collieries at a Pretoria research site, for plant metallurgists weighing dry beneficiation.
A compound dry cleaning machine de-stoned low grade raw coal without using water, but separation efficiency was low, with high relative density cut points and EPM values in the order of 0.3. Misplaced material was heavy and coal below 6 mm reported to product almost indiscriminately. The unit is cheap to buy and run, needs only crushing to 50 mm, and gives high throughput.
Contents
- Introduction4
- The FGX Compound Dry Cleaning Machine5
- FGX tests conducted at Exxaro R&D8
- Results obtained10
- Matla Coal10
- Sasol Coal17
- Anglo Coal21
- Leeuwpan Coal23
- Discussion of results25
- Conclusion29
How it opens
With the kind co-operation of Exxaro, a series of tests was conducted on a FGX compound dry cleaning machine at the Exxaro R&D site in Pretoria West. The purpose of the tests was to evaluate the potential of the FGX towards dry de-stoning of low-grade raw coals.
How it concludes
R1500,00
Description
Related Products
Evaluate the Remaining Resources of Low Phosphorus Coal in Mpumalanga Province
2004
Assessment of remaining metallurgical grade coal in the Witbank, Highveld and Ermelo coalfields from national borehole records, for resource planners and buyers of reductant coal.
What this report foundTonnage estimates for the remaining low phosphorus resource could not be produced, because the phosphorus analyses supplied by mining companies did not state...
R1500,00
Tonnage estimates for the remaining low phosphorus resource could not be produced, because the phosphorus analyses supplied by mining companies did not state what had been measured. Distribution trends were still mapped. Coal at or below 0.010 per cent phosphorus is widespread in the Witbank Coalfield, restricted to the far northwestern Highveld, and follows a northwest to southeast band in eastern Ermelo.
Dry Screening Tests Conducted With a Bivi-tec Screen
2008
Screening trials at two South African collieries, one on a small test unit and one on a full scale installation, for plant staff handling fine, damp coal.
What this report foundFine coal was screened at small apertures while surface moisture stayed below about 5 per cent.
R1500,00
200820 pages
Fine coal was screened at small apertures while surface moisture stayed below about 5 per cent. Above that, fines adhered to the coarser particles and screening became very difficult. The dual vibrating polyurethane mats stopped blinding and clogging, so screening area stayed available, but the screen action still could not dislodge fines from very damp coal.
Determine Possible Means to Conduct Large Scale Frictional Ignitions Tests, and the Value of These to Coaltech
2017
A scoping exercise based on technical enquiries to mine safety organisations and discussions at an international conference, aimed at rock engineers and safety practitioners weighing test facility investment.
What this report foundNo operating full scale frictional ignition test facility was found anywhere in the world, and building one was judged expensive, impractical and unlikely to...
R1500,00
No operating full scale frictional ignition test facility was found anywhere in the world, and building one was judged expensive, impractical and unlikely to justify its cost against laboratory scale testing. Effort should instead go to small scale laboratory equipment using South African rocks, and to expanding geological data such as silica distribution and petrographic analysis.