Coaltech Research Association

Characterization of Spontaneous Combustion Emissions

Aircraft and ground monitoring at a working colliery in summer and winter, measuring trace gases and particulates from spontaneous combustion, for air quality management and mine planning.

by Dr Luanne Otter, Dr Stuart Piketh, Ms Thabile Dlamini and Mr Roelof Burger | February 2005

What this report found

Aircraft and ground based measurements at Kleinkopje Colliery showed spontaneous combustion to be a significant source of fine particles, with PM2.5 concentrations 91 per cent higher inside a combustion plume than outside it. Sulphur dioxide, nitrogen dioxide and carbon dioxide were also raised in plume, and benzene and toluene were detected. Average particle size was below one micron.

Description

Related Products

Evaluate the Remaining Resources of Low Phosphorus Coal in Mpumalanga Province

D.S. Xaba

2004

Assessment of remaining metallurgical grade coal in the Witbank, Highveld and Ermelo coalfields from national borehole records, for resource planners and buyers of reductant coal.

What this report foundTonnage estimates for the remaining low phosphorus resource could not be produced, because the phosphorus analyses supplied by mining companies did not state...

Hydrothermal Treatment of Coal Discards and Sewage Sludge for the Production of Advanced Materials

2023

Laboratory carbonisation tests on discard and slurry samples blended with sewage sludge, with the resulting chars tested as adsorbents for dissolved pharmaceuticals. For waste and water treatment planners.

What this report foundCo-treating coal discards with sewage sludge by hydrothermal carbonisation gave hydrochars with better physicochemical properties than treating either waste...