Coaltech Research Association

Preventing Methane Ignitions in Continuous Miner Headings

R1500,00

Description

Related Products

More Effective Use of Disposable Dust masks

Underground field trials, laboratory seal tests and operator questionnaires at two collieries, covering mask selection, fit, issue records and service time. For ventilation and occupational hygiene staff.

What this report foundDust masks worn by load haul dump operators passed 200 mg of filter loading in an average of 1.7 hours, and continuous miner, shuttle car and roofbolt...

R1500,00

R1500,00

What this report found

Dust masks worn by load haul dump operators passed 200 mg of filter loading in an average of 1.7 hours, and continuous miner, shuttle car and roofbolt operators reached the same point within two to five hours. Every mask failed laboratory fit testing. An eight hour service life is too long.

Improved Utilization of Underground Coal Reserves

Nico van Eck

2016

Working reference on high extraction methods, from stooping and rib pillar extraction to auger, punch, longwall and backfilling, drawn from South African colliery experience for mine planners.

What this report foundAbout 3.19 billion tons of coal now sits underground in pillars, growing by roughly 110 million tons a year under current bord and pillar practice.

R1500,00

R1500,00

Nico van Eck

What this report found

About 3.19 billion tons of coal now sits underground in pillars, growing by roughly 110 million tons a year under current bord and pillar practice. Pillars with a safety factor of about 1.8 or higher can be extracted successfully, and 1.5 is permissible in thin seams where the pillar width to height ratio exceeds 10.

Shopping Basket