Coaltech Research Association

TRI-FLO™ Tests Conducted at South Witbank Coal Mine

GJ de Korte

200317 pages

Trial of an imported dense medium separator installed in a fine coal pilot plant at a Witbank mine, for plant designers weighing alternatives to cyclones.

What this report found

The separator handled fine coal and produced a 28 MJ/kg product, but its measured separation efficiency was lower than that of conventional dense medium cyclones and it was harder to operate. Two efficiency tests produced no evidence that the unit outperforms cyclones on fine coal, so cyclones were recommended when the plant was rebuilt at its next site.

Preview

Contents

  • EXCUTIVE SUMMARY2
  • INTRODUCTION4
  • OPERATION OF THE TRI-FLOWTM DENSE-MEDIUM SEPARATOR4
  • TEST WORK8
  • EFFICIENCY TESTS10
  • COMMENTS14
  • CONCLUSION15
  • RECOMMENDATION15

How it opens

Jim Harrison Design Associates (JHDA), the company that will be marketing the Tri-floTM dense-medium separator in South Africa on behalf of Ecomin in Italy, requested permission to test a Tri-flo unit in the Coaltech 2020 fine coal dense-medium plant at South Witbank Coal Mine (SWC) so as to ascertain whether the Tri-flo unit would be suited to processing fine coal.

How it concludes

Open to members. Sign in to read the conclusion extract.

Description

Related Products

Fine Coal Dense-medium Cyclone Tests Conducted at Leeuwpan Coal Mine

GJ de Korte

2007

Pilot dense medium cyclone testing on fine coal inside a working spiral plant at a Mpumalanga opencast mine, ending in a full scale plant design.

What this report foundDense medium cyclones on the fine coal fraction lifted product yield well above the spiral circuit they were compared against and gave closer control of...

More Effective Use of Disposable Dust masks

Underground field trials, laboratory seal tests and operator questionnaires at two collieries, covering mask selection, fit, issue records and service time. For ventilation and occupational hygiene staff.

What this report foundDust masks worn by load haul dump operators passed 200 mg of filter loading in an average of 1.7 hours, and continuous miner, shuttle car and roofbolt...

Simulation of Regional Collapses in Bord & Pillar Workings

BECK Engineering

2018

Three dimensional modelling of a documented subsidence event in the Witbank coalfield, aimed at reserves in the seam above old workings that current pillar strength formulae sterilise.

What this report foundFinite element simulation reproduced the rapid collapse of bord and pillar workings in the 2 Seam at a Witbank colliery, showing that progressive pillar...

Intra-seam Sedimentological Controls on Coal Quality: 2 Seam, Witbank Coalfield

Mark Grodner

2003

Sub-seam mapping at an opencast colliery in the Witbank area, setting out a method geologists and resource estimators can apply to other seams.

What this report foundSub-seams within the No 2 Seam were characterised at a single test site using lithology, seam thickness, proximate analysis, petrography and geophysical logs...