Coaltech Research Association

TRI-FLO™ Tests Conducted at South Witbank Coal Mine

GJ de Korte

200317 pages

Trial of an imported dense medium separator installed in a fine coal pilot plant at a Witbank mine, for plant designers weighing alternatives to cyclones.

What this report found

The separator handled fine coal and produced a 28 MJ/kg product, but its measured separation efficiency was lower than that of conventional dense medium cyclones and it was harder to operate. Two efficiency tests produced no evidence that the unit outperforms cyclones on fine coal, so cyclones were recommended when the plant was rebuilt at its next site.

Preview

Contents

  • EXCUTIVE SUMMARY2
  • INTRODUCTION4
  • OPERATION OF THE TRI-FLOWTM DENSE-MEDIUM SEPARATOR4
  • TEST WORK8
  • EFFICIENCY TESTS10
  • COMMENTS14
  • CONCLUSION15
  • RECOMMENDATION15

How it opens

Jim Harrison Design Associates (JHDA), the company that will be marketing the Tri-floTM dense-medium separator in South Africa on behalf of Ecomin in Italy, requested permission to test a Tri-flo unit in the Coaltech 2020 fine coal dense-medium plant at South Witbank Coal Mine (SWC) so as to ascertain whether the Tri-flo unit would be suited to processing fine coal.

How it concludes

Open to members. Sign in to read the conclusion extract.

R1500,00

Description

Related Products

Models for Predicting Methane Gas Release from Coal Seams

Alan Cook

2005

Emission factors and calculation models for national greenhouse gas reporting, built from mine seam gas measurements and ventilation sampling, for environmental staff and inventory compilers.

What this report foundEmission factors derived from measured South African seam gas data give simple models for methane released by underground mining, surface mining and coal after...

R1500,00

R1500,00

Alan Cook

What this report found

Emission factors derived from measured South African seam gas data give simple models for methane released by underground mining, surface mining and coal after mining. Applied across the industry they put total methane emissions at 52 000 to 93 000 tons a year. The models follow the IPCC Tier 2 approach using country specific factors.

Application of EARTH Ion Exchange Technology to Process RO (Hipro) Brine from eWRP

EARTH

2010

Pilot trial on brine from a working water reclamation plant on the Mpumalanga coalfield, the first of four studies testing ion exchange on coal mine liquors.

What this report foundIon exchange applied to brine from a three stage reverse osmosis plant at eMalahleni converted the brine entirely into saleable fertiliser and explosives...

R1500,00

R1500,00

EARTH

What this report found

Ion exchange applied to brine from a three stage reverse osmosis plant at eMalahleni converted the brine entirely into saleable fertiliser and explosives feedstock, and recovered close to half of the water the reverse osmosis stage leaves behind. On this basis the existing brine pond and the two planned for the plant expansion would not be needed.

GJ de Korte

Shopping Basket