Screening trials at two South African collieries, one on a small test unit and one on a full scale installation, for plant staff handling fine, damp coal.
Fine coal was screened at small apertures while surface moisture stayed below about 5 per cent. Above that, fines adhered to the coarser particles and screening became very difficult. The dual vibrating polyurethane mats stopped blinding and clogging, so screening area stayed available, but the screen action still could not dislodge fines from very damp coal.
Contents
- EXECUTIVE SUMMARY2
- 1. Introduction4
- 2. Bivi-Tec screen5
- 3. Test work at Leeuwpan7
- Results obtained7
- 4 The influence of moisture on screening9
- 5 Bivi-tec Screen at New Clydesdale Colliery14
- 6 Conclusions19
- 7 Acknowledgement20
- 8 References20
How it opens
Dry screening of fine coal at small screen apertures is known to be difficult. Blinding and clogging of the screen surface occurs and the screening efficiency can be very low. The Bivi-tec screen has been named as a possible solution for dry screening of fine coal since the dual-vibratory polyurethane mats eliminate blinding.
How it concludes
R1500,00
Description
Related Products
A technology to condition plants with adapted Rhizospheric soil/substrate bacterial species to improve vegetation resilience and growth on rehabilitated land
2024
Review and proposed method for using soil microbial communities to establish lasting vegetation on coal waste substrates where topsoil is scarce. For rehabilitation and closure practitioners.
What this report foundConventional rehabilitation relies on lime, fertiliser and compost to build fertility and select adaptive species, which produces short term cover but rarely a...
R1500,00
Conventional rehabilitation relies on lime, fertiliser and compost to build fertility and select adaptive species, which produces short term cover but rarely a self sustaining ecosystem. The work argues for treating soil microbes as part of the system, since bacteria drive nutrient cycling, organic matter breakdown and soil aggregation, and proposes conditioning plants with adapted rhizosphere bacteria on coal waste substrates.
Application of Earth ion Exchange Technology for Conversion of Ro Brine From Tutuka/new Denmark Into Saleable Products
2010
Pilot trial on single stage reverse osmosis brine at a Mpumalanga power station treating acid drainage from a neighbouring colliery, with projections for the planned second stage.
What this report foundIon exchange converted reverse osmosis brine from a power station treating colliery water and cooling tower blowdown into fertiliser and explosives salts, with...
R1500,00
Ion exchange converted reverse osmosis brine from a power station treating colliery water and cooling tower blowdown into fertiliser and explosives salts, with no liquid effluent left to dispose of. Part of the water rejected by the reverse osmosis stage was also recovered as potable water. Brine is currently used for dust suppression and stored underground.