Dry Screening Tests Conducted With a Bivi-tec Screen
200820 pages
Screening trials at two South African collieries, one on a small test unit and one on a full scale installation, for plant staff handling fine, damp coal.
Fine coal was screened at small apertures while surface moisture stayed below about 5 per cent. Above that, fines adhered to the coarser particles and screening became very difficult. The dual vibrating polyurethane mats stopped blinding and clogging, so screening area stayed available, but the screen action still could not dislodge fines from very damp coal.
Contents
- EXECUTIVE SUMMARY2
- 1. Introduction4
- 2. Bivi-Tec screen5
- 3. Test work at Leeuwpan7
- Results obtained7
- 4 The influence of moisture on screening9
- 5 Bivi-tec Screen at New Clydesdale Colliery14
- 6 Conclusions19
- 7 Acknowledgement20
- 8 References20
How it opens
Dry screening of fine coal at small screen apertures is known to be difficult. Blinding and clogging of the screen surface occurs and the screening efficiency can be very low. The Bivi-tec screen has been named as a possible solution for dry screening of fine coal since the dual-vibratory polyurethane mats eliminate blinding.
How it concludes
R1500,00
Description
Related Products
Review of Current and Expected Underground Coal Mining Methods and an Evaluation of the Best Practices Associated with These
2010
Review of underground coal production systems in South Africa set against practice in Australia, China and the United States, with guidance on equipment choice and section planning.
What this report foundSouth African underground sections average about 60 000 t a month, against 130 000 to 160 000 t for single pass bolter miner units on continuous haulage, while...
R1500,00
South African underground sections average about 60 000 t a month, against 130 000 to 160 000 t for single pass bolter miner units on continuous haulage, while the better sections target 1.4 to 1.6 Mt a year. Australian longwalls deliver 5 to 7 Mt a year from one face, compared with 3 to 5 Mt at the two local wall operations.
Development of a Horizontal Winnower for the Beneficiation of Fine Coal
Proof of concept work on dry beneficiation of minus 6 mm coal, combining airflow modelling and simulation with a laboratory winnowing box, for plants short of process water.
What this report foundHorizontal air winnowing separated fine coal by particle size and density in laboratory experiments, supported by equation of motion modelling and...
R1500,00
Horizontal air winnowing separated fine coal by particle size and density in laboratory experiments, supported by equation of motion modelling and computational fluid dynamics. Modelling indicated that a chamber 0.6 m high and 1 m long is sufficient to displace any minus 6 mm particle at air velocities of 10 to 30 m/s.